Product Identification
Product ID:WEED CONTROL PLUS FERTILIZER, 32-4-3
MSDS Date:05/06/1986
FSC:6850
NIIN:00B190064
MSDS Number: BQFLG
Responsible Party
MARYSVILLE, OH 43041
US
Emergency Phone: 513-644-0011
Info Phone: 513-644-0011
Cage: OMSCO
Contractor
Telephone: 513-644-0011
Cage: OMSCO
Ingredients
DICAMBA (SARA III)
CAS: 1918-00-9
RTECS: DG7525000
Fraction By Weight: 0.048%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
UREA
CAS: 57-13-6
RTECS: YR6250000
2-(2-METHYL-4-CHLOROPHENOXY)PROPIONIC ACID
CAS: 93-65-2
Fraction By Weight: 1.220%
2,4-D (DICHLORYLPHENOXYACETIC ACID) (SARA III)
CAS: 94-75-7
RTECS: AG6825000
Fraction By Weight: 1.220%
OSHA PEL 10 MG/M3
ACGIH TLV: 10 MG/M3; 9192
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POSSIBLE NAUSEA, VOMITING OR DIARRHEA.
SEVERE POISONINGS INCLUDE COMA, CONVULSIONS, HYPOREFLEXIA,
MYOTONIA, URINARY INCONTINENCE, FALL IN BLOOD PRESSURE.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:MAY CAUSE EYE, SKIN & RESPIRATORY TRACT
IRRITATION. MAY ALSO CAUSE HEADACHE, DIZZINESS AND NAUSEA.
ASPIRATION PNEUMONITIS MAY CAUSE COUGHING, LABORED BREATHING,
CYANOSIS, AND IN SEVERE CASES, DEATH.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE SKIN MAY BE AT
INCREASED RISK FROM EXPOSURE.
First Aid
First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WITH
SOAP AND WATER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ADVICE.
INHALATIO N: REMOVE TO FRESH AIR. GIVE MOUTH-TO-MOUTH RESUSCITATION
IF NOT BREATHING. GET MEDICAL ATTENTION. INGESTION: INDUCE
VOMITING. RINSE MOUTH & DRINK LARGE AMOUNTS OF WATER. GET MEDICAL
ATTENTION.
Fire Fighting
Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.
Accidental Release
Spill Release Procedures:SWEEP UP SMALL SPILLS. WEAR GLOVES, GOGGLES &
RESPIRATOR. VENTILATE AREA. DO NOT BREATHE VAPOR.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP
CONTAINERS CLOSED WHEN MATERIAL IS NOT IN USE. KEEP AWAY FROM
IGNITION SOURCES. AVOID PROLONGED OR REPEATED CONTACT.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:NA
Ventilation:NA
Protective Gloves:NA
Eye Protection:NA
Other Protective Equipment:NA
Work Hygienic Practices:NA
Supplemental Safety and Health
NA
Chemical Properties
HCC:C3
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:NA
pH:NA
Evaporation Rate & Reference:NA
Solubility in Water:NA
Appearance and Odor:GRANULAR
Percent Volatiles by Volume:NA
Stability
Stability Indicator/Materials to Avoid:YES
NA
Stability Condition to Avoid:NA
Hazardous Decomposition Products:UREA AND METHYLENE UREA NITROGEN
SOURCES CAN GENERATE AMMONIA IN A FIRE.
Disposal
Waste Disposal Methods:DISPOSAL OF WASTE AND HAZARDOUS MATERIAL SHALL
COMPLY WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL PROTECTION
AGENCY REGULATIONS. SEND WASTE MATERIAL TO AN APPROVED RECYCLING
FACILITY IF FEASIBLE. CITY , STATE AND FEDERAL REGULATIONS MUST
BEFOLLOWED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.